How long does it take a water heater to heat up?
Short answer: A 40- to 50-gallon gas tank typically reheats a full tank in about 50 to 80 minutes, and a 4,500-watt electric tank in about 1.8 to 2.3 hours, based on Bradford White, Rheem and A.O. Smith recovery ratings at a 90°F rise. A.O. Smith's own guide quotes faster times. Heat pump models are slower in heat-pump-only mode, and tankless units heat on demand with no tank to refill.
Skip to what to buy (4 types) ↓
How long does it take a water heater to heat up?
For a standard tank water heater starting from a full tank of cold water, plan on roughly:
- Gas, 40 to 50 gallons: about 50 to 80 minutes
- Electric, 40 to 50 gallons (4,500-watt elements): about 1.8 to 2.3 hours
- Heat pump, heat-pump-only mode: several hours; with the backup element, about 2 hours
- Tankless: no tank to reheat; hot water starts within seconds once water flows
These ranges are our math from manufacturers’ published recovery ratings, explained below. Real times are often shorter, because a tank is rarely completely cold. After a shower, the heater only has to reheat the water you used.
A.O. Smith’s consumer guide quotes faster numbers than this spec-sheet math, including the math from A.O. Smith’s own electric spec sheet. We show both so you can see the spread.
What does “recovery rate” mean?
Two numbers on a spec sheet tell you how fast a tank heater makes hot water:
- Recovery rate: how many gallons the heater can warm in one hour. State Water Heaters defines it as converting the heater’s BTU or watt input “into gallons heated per one hour (GPH),” at a 90°F temperature rise, meaning incoming water is warmed by 90°F (for example, from 30°F to 120°F).
- First hour rating (FHR): the gallons of hot water a tank can deliver in one busy hour. State says it “combines the heater’s Rated Storage Volume with its Recovery during one hour of operation.” DOE says to size a tank by FHR; see what size water heater do I need.
State lists recoveries of 31 to 81 GPH for its gas models and just 7.5 to 25 GPH for electric models. That gap is why gas tanks reheat so much faster.
How long does a gas vs. electric tank take? (spec-sheet math)
The simple formula, our math:
Hours to reheat = tank gallons ÷ recovery gallons per hour
We used the rated storage volume (the tested gallons), which is slightly less than the nameplate size.
| Heater (source) | Input | Rated gallons | Recovery at 90°F rise | Full-tank reheat, our math |
|---|---|---|---|---|
| Bradford White RG240T6N, 40-gal gas | 40,000 BTU/hr | 38 | 43 GPH | 38 ÷ 43 = about 53 min |
| Bradford White RG250T6N, 50-gal gas | 40,000 BTU/hr | 48 | 43 GPH | 48 ÷ 43 = about 67 min |
| Bradford White RG250S6N, 50-gal gas | 50,000 BTU/hr | 47 | 54 GPH | 47 ÷ 54 = about 52 min |
| Rheem XG50T06DV36U0, 50-gal gas direct vent | 36,000 BTU/hr | 48 | 36.4 GPH | 48 ÷ 36.4 = about 79 min |
| A.O. Smith ENLB-50, 50-gal electric | 4,500 W | 48 | 21 GPH | 48 ÷ 21 = about 2 hr 17 min |
An electric tank’s recovery depends on element wattage, not tank size. A 40-gallon electric tank with the same 4,500-watt element would take about 38 ÷ 21 = 1.8 hours, our math.
Why so slow? Most home electric tanks have two elements. Bradford White’s electric service manual says double-element heaters can be wired to run one element at a time (“Non-Simultaneous”) or both at once. In non-simultaneous mode, when the tank is cold, the upper element is energized first, heating the top of the tank, and only then is power switched to the lower element. A.O. Smith’s 21 GPH rating for its dual-element 4,500-watt tank matches the output of one element running, per the BTU math below.
Our take: because the upper element heats the top first, some usable hot water arrives well before the whole tank is done.
How the manufacturers’ quick estimates compare
| Source | Gas 40-50 gal | Electric 40-50 gal |
|---|---|---|
| A.O. Smith consumer guide | 30-40 minutes | 60-90 minutes (a second A.O. Smith page says 60-80 from empty) |
| Spec-sheet math above (90°F rise) | About 52-79 minutes | About 1.8-2.3 hours |
A.O. Smith’s guide also says a 75-gallon gas tank needs “closer to an hour” and a 75- to 80-gallon electric tank “up to 2 hours.” Its page doesn’t show the temperature rise behind its numbers. With a smaller rise, such as warm summer inlet water, times drop toward its range, as the BTU math shows.
How do you calculate heat-up time with BTUs?
It takes 1 BTU to warm 1 pound of water by 1°F, and a gallon of water weighs about 8.34 pounds. So, our math:
Hours = (gallons × 8.34 × °F rise) ÷ (input BTU per hour × efficiency)
Gas example. Bradford White says its atmospheric gas models have recovery efficiency “ranging up to 80%.” A 40,000 BTU burner at 80% puts about 32,000 BTU per hour into the water.
- Check against the spec sheet: 32,000 ÷ (8.34 × 90) = about 43 GPH. That matches Bradford White’s 43 GPH rating.
- Reheating 38 gallons from 50°F to 120°F (a 70°F rise): 38 × 8.34 × 70 = 22,184 BTU. Divided by 32,000 = about 0.69 hours, or 42 minutes.
Electric example. One watt equals about 3.412 BTU per hour, so a 4,500-watt element is about 15,354 BTU per hour. We assumed nearly all of that heat goes into the water.
- Check: 15,354 ÷ (8.34 × 90) = about 20.5 GPH, close to A.O. Smith’s 21 GPH.
- Reheating 48 gallons with a 70°F rise: 48 × 8.34 × 70 = 28,022 BTU. Divided by 15,354 = about 1.8 hours, or 110 minutes.
The 120°F target follows DOE’s suggestion for most uses; see what temperature to set your water heater.
Why does a water heater take longer in winter?
Your heater has to warm whatever comes out of the water main, and that water is colder in winter.
- DOE says that unless you know otherwise, assume incoming water is 50°F.
- The federal test procedure for water heaters uses 58°F supply water heated to 125°F, a 67°F rise (10 CFR Part 430, Appendix E).
- NREL researchers found mains temperature is driven mainly by outdoor air temperature. In their data, it averaged about 6°F above the local annual average air temperature and rose and fell with the seasons, swinging roughly 0.4 times as much as the air does.
- Rinnai’s average ground water temperature map runs from 35°F to 77°F across the U.S. and Canada, with 35-42°F for Alaska and 75°F for Hawaii and Puerto Rico. Rinnai notes actual inlet temperature can vary locally and with the seasons.
Here is what that does to a 40-gallon gas tank (38 rated gallons, 32,000 BTU per hour delivered) heating to 120°F, our math:
| Incoming water | Rise to 120°F | 40-gal gas reheat | 50-gal electric reheat (48 gal, 4,500 W) |
|---|---|---|---|
| 70°F (warm summer) | 50°F | About 30 min | About 78 min |
| 50°F (DOE default) | 70°F | About 42 min | About 110 min |
| 40°F (cold winter) | 80°F | About 48 min | About 125 min |
| Spec-sheet rating basis | 90°F | About 54 min | About 141 min |
Bradford White’s service manual lists “very cold inlet water to heater” as a cause of not enough hot water. A.O. Smith says winter recovery times are naturally longer because groundwater is colder in January than in July.
How long does a heat pump water heater take?
A heat pump water heater (also called a hybrid) pulls heat from the surrounding air with a small compressor and has electric elements as backup. The compressor is efficient but slow.
| Model (source) | Recovery at 90°F rise |
|---|---|
| Bradford White RE2H50S10, 50 gal, compressor only | 6 GPH |
| Same model, compressor plus element | 24 GPH |
| Rheem XE50T10H22U0, 50 gal (2,250 W element) | 16 GPH, mode not stated |
| Rheem XE50T10H45U1, 50 gal (4,500 W element) | 27 GPH, mode not stated |
Bradford White bases its ratings on 67.5°F surrounding air at 50% humidity; colder air slows a heat pump further. For the Bradford White 50-gallon model (45 rated gallons), our math: 45 ÷ 6 = about 7.5 hours on the compressor alone, versus 45 ÷ 24 = about 1.9 hours with the element helping.
The modes change the answer:
- Heat pump only. Rheem says this mode has “Slower recovery time.” GE says, “The time required to heat water is longer in this mode.”
- Hybrid or Energy Saver. GE says the unit “uses the heat pump unless the majority of hot water is consumed and a fast recovery is needed.”
- High Demand or Electric. Faster. GE says Standard Electric heats “faster than all other modes” but is the least efficient.
Bradford White notes its heat pump runs in air from 35°F to 120°F and switches to electric outside that range.
Do tankless water heaters need to heat up?
No. DOE says tankless units “heat water instantaneously without the use of a storage tank.” There is nothing to refill, so a tankless heater never runs out the way a tank does. You still wait a few seconds for hot water to travel through the pipes, as A.O. Smith notes.
The limit is flow, not time. DOE says tankless heaters typically deliver 2 to 5 gallons per minute, and gas models produce higher flow rates than electric ones. DOE says they are rated by the maximum temperature rise possible at a given flow rate. Colder inlet water means less hot water per minute: Rinnai’s chart for its 199,000 BTU model lists a maximum flow of about 8.8 gallons per minute with 77°F ground water but 4.4 with 35°F ground water. DOE warns that even the largest gas-fired model sometimes can’t keep up with several uses at once; running a shower and a dishwasher together can stretch a tankless heater to its limit. Compare the two types in tankless vs. tank water heater.
How long after a shower for hot water to come back?
You only reheat what you used. Suppose a shower pulls 15 gallons of hot water from the tank. Our math:
- Gas at 43 GPH: 15 ÷ 43 = about 21 minutes
- Electric at 21 GPH: 15 ÷ 21 = about 43 minutes
- Heat pump on the compressor alone at 6 GPH: 15 ÷ 6 = about 2.5 hours
Hot water is usable sooner, because the tank still holds hot water above the cold water coming in. To see how much hot water and energy your own showers use, try our shower cost calculator.
How long after a new install, a pilot relight, or a power outage?
- New install: the tank starts full of cold water, so expect the full-tank times above. A.O. Smith says a new unit should meet the recovery times in the manufacturer’s handbook. If it doesn’t, A.O. Smith says the heater may be the wrong size for your household.
- Pilot went out: once relit, the burner works at its normal recovery rate. Our take: the water has usually only cooled partway, so it often comes back faster than a cold start. See how to light a water heater pilot light.
- Power restored (electric): the upper element heats first. Our take: expect some warm water at the taps sooner and a full tank within the electric times above.
When does slow heat-up mean a problem?
If your heater used to keep up and now doesn’t, check for these causes. The Bradford White electric service manual and A.O. Smith’s guide name them.
| Symptom | Likely cause (source) |
|---|---|
| Slow recovery | Sediment or lime on elements or the tank bottom (Bradford White; A.O. Smith) |
| No hot water at all (electric) | Failed upper element or thermostat (Bradford White) |
| Some hot water, runs out fast (electric) | Failed lower element (Bradford White) |
| Lukewarm water, slow heating | Thermostat set too low or failed (Bradford White; A.O. Smith) |
| Hot water runs cold quickly | Broken dip tube, the pipe that carries cold water to the tank bottom (A.O. Smith; Bradford White) |
| Slow after an element replacement | Lower-wattage (“derated”) element installed (Bradford White) |
| Never enough in busy hours | Heater too small for demand (Bradford White; A.O. Smith) |
Bradford White says slow recovery in an electric heater “can usually be traced back to sediment or lime build up around heating element.” Flushing helps; see how to flush a water heater. An older tank that can no longer keep up may be near the end; see how long does a water heater last.
When to call a pro
Electric water heaters run on 240 volts. Turn off the breaker before opening an element cover, and leave element and thermostat testing to a qualified person if you aren’t comfortable with live circuits. A.O. Smith recommends a certified technician to replace failed elements. For gas heaters, call a licensed plumber or your gas utility for a gas smell or a burner that won’t stay lit.
What to buy
The main types, who each one suits, and what to check before you buy. Each link opens matching products at that store.
Digital multimeter
Best for: testing electric water heater elements for continuity after the power is shut off at the breaker.
Look for: resistance (ohms) and voltage modes, and probes rated for 240-volt circuits.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
Water heater heating element
Best for: replacing a failed upper or lower element in an electric tank.
Look for: the exact voltage and wattage printed on your heater's rating label; Bradford White lists a derated element as a cause of slow recovery.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
Water heater element wrench
Best for: removing screw-in elements without damaging the tank fitting.
Look for: a socket that fits your element's hex head and a long handle for leverage.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
Washing machine or drain hose for flushing
Best for: draining sediment that slows recovery.
Look for: a hose long enough to reach a floor drain or outdoors, with a threaded end that fits the drain valve.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
These links open search results at Amazon, Walmart, The Home Depot, Lowe's and Best Buy. We do not earn anything from them, and no brand paid to be listed.
Quick answers
- How long does it take a 50 gallon water heater to heat up?
- About 50 to 80 minutes for a typical 50-gallon gas tank and about 2.3 hours for a 4,500-watt electric tank, our math from Bradford White, Rheem and A.O. Smith recovery ratings at a 90°F rise. A.O. Smith's consumer guide quotes 30 to 40 minutes for gas and 60 to 90 minutes for electric.
- How long does it take an electric water heater to heat up?
- A standard 4,500-watt element recovers about 21 gallons per hour at a 90°F rise, per A.O. Smith's spec sheet, so a 40- to 50-gallon tank takes roughly 1.8 to 2.3 hours from cold, our math. A.O. Smith's own guide gives 60 to 90 minutes.
- How long does a gas water heater take to heat up?
- Common 40,000 BTU gas tanks recover about 43 gallons per hour at a 90°F rise, per Bradford White, so a 40-gallon tank reheats in about 53 minutes and a 50-gallon in about 67 minutes, our math. A.O. Smith says 30 to 40 minutes for 40 to 50 gallons.
- How long after a shower for hot water to come back?
- It depends on how much hot water the shower used and the heater's recovery rate. If a shower pulls 15 gallons of hot water, a gas tank recovering 43 gallons per hour replaces it in about 21 minutes and a 21-gallon-per-hour electric tank in about 43 minutes, our math.
- Why is my water heater taking so long to heat up?
- Colder winter inlet water, sediment, a failed heating element or thermostat, a broken dip tube, or a heater too small for your use. Bradford White's service manual lists sediment on the elements as the usual cause of slow recovery in electric heaters.
- How long does it take a heat pump water heater to heat up?
- Much longer in heat-pump-only mode. Bradford White rates its 50-gallon heat pump model at 6 gallons per hour from the compressor alone versus 24 with an element helping, so a full tank takes about 7.5 hours on the compressor alone and about 2 hours with the element, our math.
- Do tankless water heaters need time to heat up?
- No tank needs reheating. DOE says tankless units heat water as it flows, typically at 2 to 5 gallons per minute, though you still wait for hot water to travel through the pipes.
Sources
- State Water Heaters: Glossary of terms (first hour rating, recovery at 90° rise)
- Bradford White: Residential atmospheric vent gas water heater specifications
- Rheem: Performance direct vent 50-gallon gas water heater specification sheet
- A.O. Smith: ProMax lowboy 50-gallon electric water heater specification sheet
- Bradford White: AeroTherm hybrid electric heat pump water heater specification sheet (RE2H50S10)
- Rheem: Hybrid electric heat pump water heater specifications (2,250 W element models)
- Rheem: Hybrid electric heat pump water heater specifications (4,500 W element models)
- Rheem: Heat pump water heater modes explained
- GE Appliances: GeoSpring hybrid heat pump water heater operation modes
- U.S. Department of Energy, Energy Saver: Sizing a new water heater
- U.S. Department of Energy, Energy Saver: Tankless or demand-type water heaters
- 10 CFR Appendix E to Subpart B of Part 430: Uniform test method for water heaters (Cornell LII)
- NREL (Burch and Christensen): Towards development of an algorithm for mains water temperature
- Rinnai: North America ground water temperature map
- Bradford White: Residential electric water heater service manual
- A.O. Smith: How long does it take a water heater to heat up?
- A.O. Smith: How long does it take to heat up a water heater?