Short answer: To light a water heater pilot light, follow the label on your heater. Most manuals (Rheem, State, White-Rodgers) say: turn the gas knob to OFF, wait 5 or 10 minutes, smell for gas, turn to PILOT, press and hold the knob while you spark the igniter, then keep holding about 1 minute after it lights before turning to ON. Some A.O. Smith models instead have you spark for up to 90 seconds until a status light blinks.

Skip to what to buy (4 types) ↓

How to light a water heater pilot light

Follow the lighting label on your own water heater. Every gas tank heater has one, usually on the front near the gas control knob. The State GS6 manual says: “Lighting and operating instructions are located on front of the water heater.” Wait times, knob directions and hold times differ between models, so the label beats any general guide, including this one.

That said, most standing-pilot heaters use the same basic sequence. Here it is, assembled from Rheem, State, A.O. Smith and White-Rodgers instructions:

  1. Read the safety warnings on the label first. Rheem’s PVG manual opens with “STOP!” and warns that not following the directions exactly can cause “a fire or explosion.”
  2. Turn the gas control knob to OFF. Use only your hand. The Rheem and A.O. Smith manuals say never to use tools, and Rheem says if the knob won’t push in or move by hand, don’t try to repair it; call a qualified service technician.
  3. Wait 5 or 10 minutes to let any gas clear. Your label says which.
  4. Smell for gas all around the heater, including at the floor. Rheem says “some gas is heavier than air and will settle on the floor.” If you smell gas, stop and leave (see below).
  5. Turn the knob to PILOT.
  6. Push the knob all the way in and hold it. On A.O. Smith’s GDV, the knob moves about 1/4 inch (6 mm).
  7. Light the pilot. Press the igniter button. State’s SBS65 manual says to press it “rapidly (4) to (5) times,” and Rheem’s Warrior manual says “several times until the pilot is lit.” Older heaters may say to light it with a match.
  8. Keep holding the knob for about 1 minute after the pilot lights.
  9. Release the knob. It should pop back up, and the pilot should stay lit.
  10. Turn the knob to ON and set the temperature. White-Rodgers says to do this “at arm’s length away.”

Can’t see the flame? Rheem’s Warrior manual says the pilot “can only be seen through the sight glass window located on the inner door.”

How long do you wait and hold the pilot button?

Here is what each manual we read says. The point of the comparison is that the numbers really do differ, so check yours.

Manual Wait after OFF How to ignite Hold after the pilot lights
Rheem Warrior gas series 5 minutes Press the piezo button several times About 1 minute
Rheem PVG (Robertshaw control) 10 minutes Match, while holding the reset button About 1 minute
State SBS65 5 minutes Press the igniter 4 to 5 times rapidly About 1 minute
White-Rodgers 37C73U control At least 5 minutes Match About 1 minute
A.O. Smith GDV (status light) 10 minutes Click the igniter about once a second, up to 90 seconds Release when the status light blinks

Our take: about one minute of holding after the pilot lights is the common figure, and the wait before relighting is either 5 or 10 minutes. If you can’t read your label, waiting the longer 10 minutes costs you nothing.

State’s SBS65 manual adds that “it may take several minutes for air to clear the lines before the pilot will light,” which is common after the gas has been off. That’s normal; keep repeating the steps your label gives.

Why do you hold the button so long?

The knob opens a small gas line to the pilot only while you hold it down. A metal sensor sitting in the pilot flame, called a thermocouple (or on some gas valves, a thermopile), tells the gas valve the pilot is burning. Holding the knob for about a minute gives that sensor time to heat up. If you let go too soon, or the sensor isn’t working, the valve shuts off the gas and the pilot goes out.

Bradford White’s troubleshooting guide says the tip of the thermocouple should be “fully engulfed by pilot flame.” That’s why a weak or misplaced pilot flame is one of the most common reasons a pilot won’t stay lit.

Can I relight a pilot light myself?

Yes, on a heater whose label gives owner lighting instructions, as long as you follow it exactly and nothing seems wrong. The manuals put those steps on the heater for the owner to use. They also set clear limits. Stop, turn the knob to OFF and call a service technician or your gas supplier if:

Repairs beyond relighting, such as testing or replacing a thermocouple or gas valve, are in service manuals that Bradford White says are “to be performed ONLY by qualified service providers.”

What to do if you smell gas near the water heater

Natural gas has no smell of its own. Connecticut’s Public Utilities Regulatory Authority explains that utilities add mercaptan, which gives it a “rotten egg” smell. If you notice it:

White-Rodgers adds two warnings: “DO NOT RELY TOTALLY ON YOUR NOSE,” and never use an open flame or spark to check for leaks. State’s manual says to use a soapy water solution instead.

Do newer water heaters have a pilot you can light?

Not always in the old way. There are three common setups:

Type How the pilot lights What you do
Older standing pilot Match or long lighter at the burner Follow the label; older Rheem PVG and White-Rodgers steps use a match
FVIR standing pilot with igniter Push-button piezo spark behind a sealed door Hold the knob and press the igniter; don’t open the inner door
Electronic ignition (for example, power vent) The control lights the pilot itself on each call for heat No hand lighting; reset or call for service per the manual

FVIR stands for flammable vapor ignition resistant. Bradford White explains that on its version, trace vapors are burned off harmlessly, a flame arrestor plate keeps flame from traveling back out of the combustion chamber, and a thermal switch shuts off the pilot and burner if vapors reach it. A.O. Smith’s GDV manual says its pilot is lit by a piezoelectric spark and warns not to open the inner door to light the pilot by hand. Bradford White says that with the inner door removed, its DEFENDER Safety System is inactive.

Status lights. Some gas valves have an LED that blinks to show the pilot is working. On A.O. Smith’s GDV, you release the knob once the status light blinks; if it turns solid red, release it and wait 10 minutes before trying again. Bradford White’s guide says that for a Honeywell valve with a solid LED after turning the knob off, “wait until LED goes out before attempting to relight.”

Electronic ignition. Rheem’s 42VP power-vent manual says the heater “is equipped with an electronically lit pilot to light the main burner.” The control makes three ignition attempts before it locks out. There’s nothing to light by hand. If yours shows an error, use the manual’s error code table or call a technician.

If you’re replacing an old heater anyway, our tankless vs. tank water heater comparison and what size water heater do I need guide cover the choice.

Why won’t my water heater pilot light stay lit?

If the pilot lights while you hold the knob but goes out when you let go, the trouble is usually the sensor that proves the flame. Bradford White’s two service manuals list these causes:

Cause What it means Who should fix it
Poor thermocouple connection at the gas valve Loose fitting where the sensor connects Technician
Thermocouple not fully seated in the pilot bracket The sensor has slipped out of position Technician
Pilot flame not fully covering the thermocouple tip Flame is weak or aimed wrong Technician
Weak or defective thermocouple The sensor no longer makes enough signal Technician (replace it)
Thermopile failure or unstable pilot (Honeywell valves) Same idea on valves with a thermopile; Bradford White says to replace the pilot assembly, then the gas valve Technician
Resettable thermal switch has opened A safety switch shut the pilot and burner off Find the cause first (see below)
Open ECO or defective magnet in the gas valve Faults inside the gas valve Technician (replace the valve)

The ECO (energy cut-off) is a safety limit built into the gas valve. Our take: several causes in a row point to the same sensor, so if your pilot repeatedly lights and then dies when you release the knob, that is the first thing a technician will check.

Why did my water heater pilot light go out?

A pilot that was working and then went out has slightly different causes. Bradford White’s DEFENDER service manual lists these for a pilot that “goes out periodically”:

Bradford White also lists a blocked pilot orifice or pilot tube as a reason a pilot fails to light, and says a blocked orifice must be cleaned or replaced, and a kinked or cracked pilot tube means the pilot must be replaced. That’s service work.

Lint, dust and the air openings

FVIR heaters draw combustion air through slot openings in the outer jacket and through a flame arrestor plate. Bradford White says to “check and clear jacket slot openings of any dirt, dust, restrictions or other obstructions.” It says severe lint, dust or oil buildup on the arrestor plate can trip the thermal switch, which shuts off the burner and pilot. Heaters near a dryer or in a dusty garage are the ones to watch, in our estimate.

Cleaning the arrestor plate itself is in Bradford White’s service manual, written for qualified service providers. Keeping the outside openings clear is something an owner can do with the heater off.

Flammable vapors and safety shutoffs

FVIR heaters are designed to shut down when flammable vapors reach them, and some won’t let you simply relight.

The fix for the cause is the same everywhere. Rheem’s manual says, “Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance,” and to keep flammable products far away, tightly closed, in approved containers and out of children’s reach. See our guide to storing gasoline safely.

Carbon monoxide and gas water heaters

A gas water heater burns fuel, so it can produce carbon monoxide (CO) if it isn’t venting or burning properly. CDC lists the most common symptoms of CO poisoning as “headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion.”

A pilot that keeps going out because of poor combustion air or a clogged vent, two causes Bradford White lists, is a venting problem, not just a nuisance. Our take: that’s a reason to call a technician rather than keep relighting.

After the pilot is back on

Quick checklist

What to buy

The main types, who each one suits, and what to check before you buy. Each link opens matching products at that store.

  1. Carbon monoxide alarm

    Best for: any home with a gas water heater, furnace or other fuel-burning appliance.

    Look for: battery-operated or battery backup power (CDC), installed in hallways near each sleeping area (CPSC).

  2. Small LED flashlight

    Best for: seeing the pilot flame through the sight glass on the burner door while you light it.

    Look for: a compact light you can hold in one hand or set down, since your other hand stays on the gas knob.

  3. Long-reach lighter

    Best for: older heaters whose lighting label says to light the pilot with a match.

    Look for: a long nozzle and child-resistant switch. Don't use one on sealed FVIR heaters; A.O. Smith says not to open the inner door to light the pilot by hand.

  4. Replacement thermocouple or pilot assembly

    Best for: a technician or experienced owner fixing a pilot that lights but won't stay lit.

    Look for: the exact part your heater's maker lists for your model; Bradford White says some Honeywell-valve heaters need the whole pilot assembly replaced.

These links open search results at Amazon, Walmart, The Home Depot, Lowe's and Best Buy. We do not earn anything from them, and no brand paid to be listed.

Quick answers

How do you relight the pilot light on a gas water heater?
Turn the gas control knob to OFF, wait 5 or 10 minutes (your label says which), and smell for gas near the floor. Turn the knob to PILOT, push it in and hold it while you press the igniter, keep holding about 1 minute after the pilot lights, then release and turn the knob to ON.
How long do you hold the pilot button on a water heater?
About one minute after the pilot lights, according to Rheem, State and White-Rodgers instructions. Some A.O. Smith models with a status light work differently: you hold the knob and click the igniter about once a second for up to 90 seconds, then release when the light starts blinking.
Why won't my water heater pilot light stay lit?
Bradford White's service guides list a weak, loose or misplaced thermocouple, a tripped thermal switch, a faulty gas valve, too little combustion air, a clogged vent and unsteady gas pressure. If it won't stay lit after several tries, the manuals say to turn the knob to OFF and call a service technician or your gas supplier.
Why did my water heater pilot light go out?
Common causes in Bradford White's service guides are a failing thermocouple or thermopile, lint or dust blocking the air openings, poor combustion air or venting, and gas supply problems. On flammable-vapor-resistant heaters, a thermal switch or vapor sensor can also shut the pilot off on purpose.
Can I relight a water heater pilot light myself?
Yes, if your heater has a lighting label for owners and you follow it exactly. Stop and call a technician or your gas supplier if you smell gas, the knob won't push in or pop back up, the pilot won't stay lit after several tries, or any part of the heater has been under water.
How long do you wait to relight a water heater pilot?
Five or ten minutes after turning the knob to OFF, depending on the label. Rheem's Warrior and State's SBS65 manuals say 5 minutes, while Rheem's PVG and A.O. Smith's GDV manuals say 10 minutes. The wait lets leftover gas clear before you make a spark.
Do newer water heaters have a pilot light?
Many do, but not all are lit the old way. Some newer FVIR heaters use a push-button igniter behind a sealed door with no access for a match, and power-vent models such as Rheem's 42VP series have an electronically lit pilot that lights itself on each call for heat.
What should I do if I smell gas near my water heater?
Don't try to light it. Leave the building and tell others to leave, don't flip light switches or use a phone inside, and call your gas company or 911 from outside or a neighbor's home, as Connecticut's utility regulator advises.

Sources