How to light a water heater pilot light, step by step
Short answer: To light a water heater pilot light, follow the label on your heater. Most manuals (Rheem, State, White-Rodgers) say: turn the gas knob to OFF, wait 5 or 10 minutes, smell for gas, turn to PILOT, press and hold the knob while you spark the igniter, then keep holding about 1 minute after it lights before turning to ON. Some A.O. Smith models instead have you spark for up to 90 seconds until a status light blinks.
Skip to what to buy (4 types) ↓
How to light a water heater pilot light
Follow the lighting label on your own water heater. Every gas tank heater has one, usually on the front near the gas control knob. The State GS6 manual says: “Lighting and operating instructions are located on front of the water heater.” Wait times, knob directions and hold times differ between models, so the label beats any general guide, including this one.
That said, most standing-pilot heaters use the same basic sequence. Here it is, assembled from Rheem, State, A.O. Smith and White-Rodgers instructions:
- Read the safety warnings on the label first. Rheem’s PVG manual opens with “STOP!” and warns that not following the directions exactly can cause “a fire or explosion.”
- Turn the gas control knob to OFF. Use only your hand. The Rheem and A.O. Smith manuals say never to use tools, and Rheem says if the knob won’t push in or move by hand, don’t try to repair it; call a qualified service technician.
- Wait 5 or 10 minutes to let any gas clear. Your label says which.
- Smell for gas all around the heater, including at the floor. Rheem says “some gas is heavier than air and will settle on the floor.” If you smell gas, stop and leave (see below).
- Turn the knob to PILOT.
- Push the knob all the way in and hold it. On A.O. Smith’s GDV, the knob moves about 1/4 inch (6 mm).
- Light the pilot. Press the igniter button. State’s SBS65 manual says to press it “rapidly (4) to (5) times,” and Rheem’s Warrior manual says “several times until the pilot is lit.” Older heaters may say to light it with a match.
- Keep holding the knob for about 1 minute after the pilot lights.
- Release the knob. It should pop back up, and the pilot should stay lit.
- Turn the knob to ON and set the temperature. White-Rodgers says to do this “at arm’s length away.”
Can’t see the flame? Rheem’s Warrior manual says the pilot “can only be seen through the sight glass window located on the inner door.”
How long do you wait and hold the pilot button?
Here is what each manual we read says. The point of the comparison is that the numbers really do differ, so check yours.
| Manual | Wait after OFF | How to ignite | Hold after the pilot lights |
|---|---|---|---|
| Rheem Warrior gas series | 5 minutes | Press the piezo button several times | About 1 minute |
| Rheem PVG (Robertshaw control) | 10 minutes | Match, while holding the reset button | About 1 minute |
| State SBS65 | 5 minutes | Press the igniter 4 to 5 times rapidly | About 1 minute |
| White-Rodgers 37C73U control | At least 5 minutes | Match | About 1 minute |
| A.O. Smith GDV (status light) | 10 minutes | Click the igniter about once a second, up to 90 seconds | Release when the status light blinks |
Our take: about one minute of holding after the pilot lights is the common figure, and the wait before relighting is either 5 or 10 minutes. If you can’t read your label, waiting the longer 10 minutes costs you nothing.
State’s SBS65 manual adds that “it may take several minutes for air to clear the lines before the pilot will light,” which is common after the gas has been off. That’s normal; keep repeating the steps your label gives.
Why do you hold the button so long?
The knob opens a small gas line to the pilot only while you hold it down. A metal sensor sitting in the pilot flame, called a thermocouple (or on some gas valves, a thermopile), tells the gas valve the pilot is burning. Holding the knob for about a minute gives that sensor time to heat up. If you let go too soon, or the sensor isn’t working, the valve shuts off the gas and the pilot goes out.
Bradford White’s troubleshooting guide says the tip of the thermocouple should be “fully engulfed by pilot flame.” That’s why a weak or misplaced pilot flame is one of the most common reasons a pilot won’t stay lit.
Can I relight a pilot light myself?
Yes, on a heater whose label gives owner lighting instructions, as long as you follow it exactly and nothing seems wrong. The manuals put those steps on the heater for the owner to use. They also set clear limits. Stop, turn the knob to OFF and call a service technician or your gas supplier if:
- You smell gas at any point.
- The knob won’t push in or turn by hand. Rheem warns that “force or attempted repair may result in a fire or explosion.”
- The knob doesn’t pop back up when you release it. For its reset button, Rheem’s PVG manual says to “stop and immediately shut off the gas at the line valve or tank” and call for service. Rheem’s Warrior manual says to stop and call your service technician or gas supplier.
- The pilot won’t stay lit after several tries. Rheem, State and White-Rodgers all say this.
- A.O. Smith GDV status light fails three times. If it doesn’t blink within 90 seconds, repeat up to three times, waiting 10 minutes between attempts, then call a technician or your gas supplier.
- Any part of the heater has been under water. A.O. Smith says to have a qualified installer or service agency replace a flooded water heater. Rheem says not to run it until a qualified service technician has checked it, and to replace any part of the gas control system that was under water.
Repairs beyond relighting, such as testing or replacing a thermocouple or gas valve, are in service manuals that Bradford White says are “to be performed ONLY by qualified service providers.”
What to do if you smell gas near the water heater
Natural gas has no smell of its own. Connecticut’s Public Utilities Regulatory Authority explains that utilities add mercaptan, which gives it a “rotten egg” smell. If you notice it:
- Don’t try to light the heater or any other appliance (Rheem, A.O. Smith, White-Rodgers).
- Leave the building and tell others to leave if the smell is strong or you’re unsure.
- Don’t flip light switches on or off, use the doorbell, or adjust thermostats or appliance controls (Connecticut PURA).
- Don’t use a phone inside the building. Call your gas company or 911 from a neighbor’s home or somewhere away from the smell. If you can’t reach your gas supplier, Rheem and A.O. Smith say to call the fire department.
- Don’t smoke, strike matches or light candles.
White-Rodgers adds two warnings: “DO NOT RELY TOTALLY ON YOUR NOSE,” and never use an open flame or spark to check for leaks. State’s manual says to use a soapy water solution instead.
Do newer water heaters have a pilot you can light?
Not always in the old way. There are three common setups:
| Type | How the pilot lights | What you do |
|---|---|---|
| Older standing pilot | Match or long lighter at the burner | Follow the label; older Rheem PVG and White-Rodgers steps use a match |
| FVIR standing pilot with igniter | Push-button piezo spark behind a sealed door | Hold the knob and press the igniter; don’t open the inner door |
| Electronic ignition (for example, power vent) | The control lights the pilot itself on each call for heat | No hand lighting; reset or call for service per the manual |
FVIR stands for flammable vapor ignition resistant. Bradford White explains that on its version, trace vapors are burned off harmlessly, a flame arrestor plate keeps flame from traveling back out of the combustion chamber, and a thermal switch shuts off the pilot and burner if vapors reach it. A.O. Smith’s GDV manual says its pilot is lit by a piezoelectric spark and warns not to open the inner door to light the pilot by hand. Bradford White says that with the inner door removed, its DEFENDER Safety System is inactive.
Status lights. Some gas valves have an LED that blinks to show the pilot is working. On A.O. Smith’s GDV, you release the knob once the status light blinks; if it turns solid red, release it and wait 10 minutes before trying again. Bradford White’s guide says that for a Honeywell valve with a solid LED after turning the knob off, “wait until LED goes out before attempting to relight.”
Electronic ignition. Rheem’s 42VP power-vent manual says the heater “is equipped with an electronically lit pilot to light the main burner.” The control makes three ignition attempts before it locks out. There’s nothing to light by hand. If yours shows an error, use the manual’s error code table or call a technician.
If you’re replacing an old heater anyway, our tankless vs. tank water heater comparison and what size water heater do I need guide cover the choice.
Why won’t my water heater pilot light stay lit?
If the pilot lights while you hold the knob but goes out when you let go, the trouble is usually the sensor that proves the flame. Bradford White’s two service manuals list these causes:
| Cause | What it means | Who should fix it |
|---|---|---|
| Poor thermocouple connection at the gas valve | Loose fitting where the sensor connects | Technician |
| Thermocouple not fully seated in the pilot bracket | The sensor has slipped out of position | Technician |
| Pilot flame not fully covering the thermocouple tip | Flame is weak or aimed wrong | Technician |
| Weak or defective thermocouple | The sensor no longer makes enough signal | Technician (replace it) |
| Thermopile failure or unstable pilot (Honeywell valves) | Same idea on valves with a thermopile; Bradford White says to replace the pilot assembly, then the gas valve | Technician |
| Resettable thermal switch has opened | A safety switch shut the pilot and burner off | Find the cause first (see below) |
| Open ECO or defective magnet in the gas valve | Faults inside the gas valve | Technician (replace the valve) |
The ECO (energy cut-off) is a safety limit built into the gas valve. Our take: several causes in a row point to the same sensor, so if your pilot repeatedly lights and then dies when you release the knob, that is the first thing a technician will check.
Why did my water heater pilot light go out?
A pilot that was working and then went out has slightly different causes. Bradford White’s DEFENDER service manual lists these for a pilot that “goes out periodically”:
- Insufficient combustion air supply. The flame needs air. Rheem’s PVG manual notes that heaters in rooms with “unusually tight construction” may still need outdoor air openings.
- An incorrect or clogged vent system, vent terminal or vent location.
- Inconsistent gas supply or gas pressure.
Bradford White also lists a blocked pilot orifice or pilot tube as a reason a pilot fails to light, and says a blocked orifice must be cleaned or replaced, and a kinked or cracked pilot tube means the pilot must be replaced. That’s service work.
Lint, dust and the air openings
FVIR heaters draw combustion air through slot openings in the outer jacket and through a flame arrestor plate. Bradford White says to “check and clear jacket slot openings of any dirt, dust, restrictions or other obstructions.” It says severe lint, dust or oil buildup on the arrestor plate can trip the thermal switch, which shuts off the burner and pilot. Heaters near a dryer or in a dusty garage are the ones to watch, in our estimate.
Cleaning the arrestor plate itself is in Bradford White’s service manual, written for qualified service providers. Keeping the outside openings clear is something an owner can do with the heater off.
Flammable vapors and safety shutoffs
FVIR heaters are designed to shut down when flammable vapors reach them, and some won’t let you simply relight.
- Bradford White DEFENDER: If vapors are present “in sufficient quantity to prevent normal combustion, the burner/pilot flame is shut down.” Its thermal switch can be reset with the red button on the inner door, but the manual says the cause must be found first, and for a flammable vapor incident its listed fix is “Replace water heater.”
- Rheem with a flammable vapor sensor: Rheem’s 75-gallon manual says the sensor “will automatically shut down the water heater in the presence of gasoline vapors” and won’t let it ignite “until examined by a Qualified Service Technician.”
- Rheem 42VP power vent: The control shows code 47 for a vapor sensor lockout. Rheem says to make sure no gasoline or flammable vapors are present, then reset with the ON/OFF switch, and to “promptly contact a qualified service technician.”
The fix for the cause is the same everywhere. Rheem’s manual says, “Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance,” and to keep flammable products far away, tightly closed, in approved containers and out of children’s reach. See our guide to storing gasoline safely.
Carbon monoxide and gas water heaters
A gas water heater burns fuel, so it can produce carbon monoxide (CO) if it isn’t venting or burning properly. CDC lists the most common symptoms of CO poisoning as “headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion.”
- Have it serviced every year. CPSC says: “Every year, have a professional inspect all fuel burning heating systems including water heaters and furnaces.” CDC also says to have them serviced by a qualified technician every year.
- Install CO alarms. CDC recommends battery-operated or battery backup CO detectors near every sleeping area, and CPSC says to put them in hallways near bedrooms. Our carbon monoxide detector placement guide covers where and how many.
- Check the batteries when you change the clocks each spring and fall (CDC).
A pilot that keeps going out because of poor combustion air or a clogged vent, two causes Bradford White lists, is a venting problem, not just a nuisance. Our take: that’s a reason to call a technician rather than keep relighting.
After the pilot is back on
- Set the temperature. Turn the knob from PILOT to ON, then to your setting. Our water heater temperature setting guide explains the trade-offs.
- Give it time. The tank has to reheat from cold, so hot water won’t be back right away.
- Relight after maintenance. If you turned the gas off to drain the tank, our how to flush a water heater steps end with relighting the pilot the same way.
- Watch for repeats. One outage after the gas was shut off is normal. Repeated outages are a service call.
Quick checklist
- Read the lighting label on your heater and follow it, not a general guide.
- Knob to OFF, wait 5 or 10 minutes, then smell for gas, including at floor level.
- Smell gas? Don’t light anything. Leave, and call your gas company or 911 from outside.
- Knob to PILOT, push in and hold, press the igniter.
- Keep holding about 1 minute after it lights (or until the status light blinks, on models that have one).
- Release, check it stays lit, then turn to ON at arm’s length.
- Won’t stay lit after several tries, knob won’t pop up, or the heater was flooded: turn it OFF and call a technician.
- Keep gasoline and other flammables away, keep the air openings clear, and have the heater inspected every year.
- Keep CO alarms near every sleeping area.
What to buy
The main types, who each one suits, and what to check before you buy. Each link opens matching products at that store.
Carbon monoxide alarm
Best for: any home with a gas water heater, furnace or other fuel-burning appliance.
Look for: battery-operated or battery backup power (CDC), installed in hallways near each sleeping area (CPSC).
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
Small LED flashlight
Best for: seeing the pilot flame through the sight glass on the burner door while you light it.
Look for: a compact light you can hold in one hand or set down, since your other hand stays on the gas knob.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
Long-reach lighter
Best for: older heaters whose lighting label says to light the pilot with a match.
Look for: a long nozzle and child-resistant switch. Don't use one on sealed FVIR heaters; A.O. Smith says not to open the inner door to light the pilot by hand.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
Replacement thermocouple or pilot assembly
Best for: a technician or experienced owner fixing a pilot that lights but won't stay lit.
Look for: the exact part your heater's maker lists for your model; Bradford White says some Honeywell-valve heaters need the whole pilot assembly replaced.
See on AmazonAlso at Walmart Home Depot Lowe's Best Buy
These links open search results at Amazon, Walmart, The Home Depot, Lowe's and Best Buy. We do not earn anything from them, and no brand paid to be listed.
Quick answers
- How do you relight the pilot light on a gas water heater?
- Turn the gas control knob to OFF, wait 5 or 10 minutes (your label says which), and smell for gas near the floor. Turn the knob to PILOT, push it in and hold it while you press the igniter, keep holding about 1 minute after the pilot lights, then release and turn the knob to ON.
- How long do you hold the pilot button on a water heater?
- About one minute after the pilot lights, according to Rheem, State and White-Rodgers instructions. Some A.O. Smith models with a status light work differently: you hold the knob and click the igniter about once a second for up to 90 seconds, then release when the light starts blinking.
- Why won't my water heater pilot light stay lit?
- Bradford White's service guides list a weak, loose or misplaced thermocouple, a tripped thermal switch, a faulty gas valve, too little combustion air, a clogged vent and unsteady gas pressure. If it won't stay lit after several tries, the manuals say to turn the knob to OFF and call a service technician or your gas supplier.
- Why did my water heater pilot light go out?
- Common causes in Bradford White's service guides are a failing thermocouple or thermopile, lint or dust blocking the air openings, poor combustion air or venting, and gas supply problems. On flammable-vapor-resistant heaters, a thermal switch or vapor sensor can also shut the pilot off on purpose.
- Can I relight a water heater pilot light myself?
- Yes, if your heater has a lighting label for owners and you follow it exactly. Stop and call a technician or your gas supplier if you smell gas, the knob won't push in or pop back up, the pilot won't stay lit after several tries, or any part of the heater has been under water.
- How long do you wait to relight a water heater pilot?
- Five or ten minutes after turning the knob to OFF, depending on the label. Rheem's Warrior and State's SBS65 manuals say 5 minutes, while Rheem's PVG and A.O. Smith's GDV manuals say 10 minutes. The wait lets leftover gas clear before you make a spark.
- Do newer water heaters have a pilot light?
- Many do, but not all are lit the old way. Some newer FVIR heaters use a push-button igniter behind a sealed door with no access for a match, and power-vent models such as Rheem's 42VP series have an electronically lit pilot that lights itself on each call for heat.
- What should I do if I smell gas near my water heater?
- Don't try to light it. Leave the building and tell others to leave, don't flip light switches or use a phone inside, and call your gas company or 911 from outside or a neighbor's home, as Connecticut's utility regulator advises.
Sources
- A.O. Smith GDV series manual: For your safety read before lighting, lighting instructions (ManualsLib)
- Rheem PVG manual: Figure 17A, lighting instructions, Robertshaw thermostat (ManualsLib)
- Rheem PVG installation, operation and service manual (ManualsLib)
- Rheem Warrior gas series use and care manual, lighting instructions (ManualOwl)
- State SBS65 65NE water heater manual, lighting instructions (ManualsDir)
- State GS6 65 XRRT water heater manual, lighting (ManualsDir)
- White-Rodgers (Emerson): Water heater thermostat control installation instructions, 37C73U (PDF)
- Bradford White: Troubleshooting guide and instructions for service, manual 238-51542-00A (PDF)
- Bradford White: DEFENDER Safety System service manual, 238-44943-00D (PDF)
- Rheem: Residential 40 and 50 gallon power vent use and care manual, AP14818-1 (PDF, InspectApedia)
- Rheem: Residential 75 gallon use and care manual, AP14460 (ManualMachine)
- Connecticut Public Utilities Regulatory Authority: What to do if you smell natural gas
- CDC: Carbon monoxide (CO) poisoning basics
- CPSC: Carbon monoxide safety (PDF)